Steady-State Performance of a Domestic Refrigerator/Freezer Using R12 and R134a
Staley, D.M.; Bullard, C.W.; Crawford, R.R.
Content Files

Loading…
Download Files
Loading…
Download Counts (All Files)
Loading…
Edit File
Loading…
Permalink
https://hdl.handle.net/2142/9723
Description
- Title
- Steady-State Performance of a Domestic Refrigerator/Freezer Using R12 and R134a
- Author(s)
- Staley, D.M.
- Bullard, C.W.
- Crawford, R.R.
- Issue Date
- 1992-06
- Keyword(s)
- analysis of refrigerator-freezer systems
- Date of Ingest
- 2009-03-13T00:39:10Z
- Abstract
- This paper develops a steady-state system design model for a standard 18 ft3 refrigerator/freezer. Models for the compressor, condenser, evaporator, and suction line interchanger are considered. Experimental data for both R12 and R134a are used as a basis to calibrate the models and as a basis of comparison of model validity for different refrigerants. For each model, a set of independent model parameters are determined from the experimental data using optimization methods. For the heat exchangers both constant conductance and variable conductance models are considered. Lastly, a preliminary overview is made of the applicability of a quasi-steady refrigerator model for use in describing normal cycling operation of a refrigerator/freezer.
- Publisher
- Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign.
- Series/Report Name or Number
- Air Conditioning and Refrigeration Center TR-22
- Type of Resource
- text
- Genre of Resource
- Technical Report
- Language
- en
- Permalink
- http://hdl.handle.net/2142/9723
- Sponsor(s)/Grant Number(s)
- Air Conditioning and Refrigeration Center Project 12