Withdraw
Loading…
Development of a meter for measurement of sewer flow
Wenzel, Harry G.
Loading…
Permalink
https://hdl.handle.net/2142/90302
Description
- Title
- Development of a meter for measurement of sewer flow
- Author(s)
- Wenzel, Harry G.
- Contributor(s)
- Burris, Bruce E.
- Morris, Charles D.
- University of Illinois at Urbana-Champaign
- Issue Date
- 1973-12
- Keyword(s)
- Water resource development--Illinois
- Water resources development
- Wastewater
- Waste water
- Flow measurement
- Sewer flow
- Flow meter
- Discharge measurement
- Urban drainage
- Geographic Coverage
- Illinois (state)
- Abstract
- An experimental and analytical study was performed to develop the geometry for a Venturi type flow meter for use in sewer flow measurement. The meter consists of a constriction in the pipe which produces critical flow under open channel flow conditions and acts as a conventional Venturi meter under full flow conditions. The constriction is constructed using cylindrical segments whose diameter are larger than that of the pipe and which are attached to the sides of the pipe, leaving the invert and crown clear. Head loss characteristics and experimental rating curves for both open channel and full flow conditions are described. A procedure is presented, based on experimental data, to theoretically construct a rating curve if experimental calibration is impractical. Information is also presented to permit the selection of geometrical parameters for optimum performance for a specific installation.
- Publisher
- University of Illinois at Urbana-Champaign. Water Resources Center
- Type of Resource
- text
- Language
- en
- Permalink
- http://hdl.handle.net/2142/90302
- Sponsor(s)/Grant Number(s)
- U.S. Department of the Interior
- U.S. Geological Survey
- Copyright and License Information
- Copyright 1973 helf by Harry G. Wenzel, Jr.