Microvascular Networks for Continuous Self -Healing Materials
Toohey, Kathleen Suzanne
This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/87742
Description
Title
Microvascular Networks for Continuous Self -Healing Materials
Author(s)
Toohey, Kathleen Suzanne
Issue Date
2007
Doctoral Committee Chair(s)
Sottos, Nancy R.
Department of Study
Theoretical and Applied Mechanics
Discipline
Theoretical and Applied Mechanics
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
Ph.D.
Degree Level
Dissertation
Keyword(s)
Engineering, Materials Science
Language
eng
Abstract
Microcapsule-based and hollow glass fiber-based self-healing composites enable a single repair of crack damage in a given location. Re-mendable polymers have demonstrated crack mending for multiple cycles, but only with heat treatment and applied pressure. We demonstrate, for the first time, the autonomic characteristics of microencapsulated systems with the ability to heal repeated damage events in a continuous self-healing coating on a microvascular substrate. A three-dimensional, interconnected microvascular network in the substrate serves as a delivery system for healing materials to heal damage in a polymer coating. Two approaches to microvascular delivery are explored: one using a fluid monomer in the network with solidphase catalyst particles in the coating, and one using two or more separate networks with two fluid healing components. In both systems, the fluid(s) flow from the microchannels into the crack plane through capillary action, and polymerization occurs to heal the crack. In the single-fluid system, a single crack in a brittle epoxy coating is healed as many as seven times, and the ability to heal continuously is limited only by the availability of catalyst. The two-part healing system contained in separate networks in a specimen has significant potential to extend the repeatability of the healing process due to the microvascular supply of both healing components. Preliminary tests of this two-part system demonstrate that multiple healing cycles are possible.