Carbon Dioxide and R410A Flow Boiling Heat Transfer, Pressure Drop, and Flow Pattern in Horizontal Tubes at Low Temperatures
Park, Chang Yong
This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/83866
Description
Title
Carbon Dioxide and R410A Flow Boiling Heat Transfer, Pressure Drop, and Flow Pattern in Horizontal Tubes at Low Temperatures
Author(s)
Park, Chang Yong
Issue Date
2006
Doctoral Committee Chair(s)
Hrnjak, Predrag S.
Department of Study
Mechanical Engineering
Discipline
Mechanical Engineering
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
Ph.D.
Degree Level
Dissertation
Keyword(s)
Engineering, Chemical
Language
eng
Abstract
Carbon dioxide (CO2) has been seriously considered as an alternate refrigerant for HCFC and HFC fluids, due to the increasing interest of environmentally safe refrigerants in air-conditioning and refrigeration systems. In this study, CO2 flow boiling heat transfer coefficients and pressure drop are measured in macro-scale (6.1 and 3.5 mm) tubes at evaporation temperatures of -15 and -30°C. The measured results show that the nucleate boiling is a main heat transfer mechanism in the 6.1 mm tube and the contribution of convective boiling becomes greater with the decrease of tube diameters and the increase of mass fluxes. The surface roughness of the 6.1 and 3.5 mm tube are presented by SEM and AFM images and surface profiles, and it is shown that the rougher surface of the 6.1 mm tube can affect the flow boiling heat transfer. The CO2 heat transfer coefficients and pressure drop are measured in a mini-scale (0.89 mm) multi-ported tube at the evaporation temperature of -30°C. Also, R410A and R22 flow boiling heat transfer coefficients and pressure drop in a macro-scale (6.1 mm) tube were measured, and they are compared with CO2. This comparison presents that the CO2 flow boiling heat transfer coefficients are higher than R410A and R22 at low vapor qualities, and CO2 pressure drop is significantly lower than R410A and R22. This advantageous characteristic for CO2 could be explained by properties such as surface tension, reduced pressure, and the density ratio of liquid to vapor. The prediction of heat transfer coefficients and pressure drop was performed by general correlations and the calculation results are compared with measured values. Two-phase flow patterns were visualized for CO2 and R410A in the 6 and 3 mm glass tubes, and they are compared with the Weisman et al. and the Wojtan et al. flow pattern maps. The flow pattern maps can determine the flow patterns relatively well, except the transition from intermittent to annular flow.
Use this login method if you
don't
have an
@illinois.edu
email address.
(Oops, I do have one)
IDEALS migrated to a new platform on June 23, 2022. If you created
your account prior to this date, you will have to reset your password
using the forgot-password link below.