Withdraw
Loading…
Doppler Broadening Thermometry Based On Cavity Ring-down Spectroscopy
Hu, Shui-Ming
Loading…
Permalink
https://hdl.handle.net/2142/51149
Description
- Title
- Doppler Broadening Thermometry Based On Cavity Ring-down Spectroscopy
- Author(s)
- Hu, Shui-Ming
- Contributor(s)
- Zhang, Jin-Tao
- Liu, An-Wen
- Sun, Yu Robert
- Tan, Yan
- Wang, Jin
- Cheng, Cunfeng
- Issue Date
- 2014-06-17
- Keyword(s)
- Instrument/Technique Demonstration
- Abstract
- A Doppler broadening thermometry is implemented using a laser-locked cavity ring-down spectrometer%~[1,2] \footnote{ H. Pan, C.-F. Cheng, Y.~R. Sun, B. Gao, A.-W. Liu, S.-M. Hu, ``Laser-locked, continuously tunable high resolution cavity ring-down spectrometer,'' Rev. Sci. Instrum. \textbf{82}, 103110 (2011)} \footnote{ Y.~R. Sun, H. Pan, C.-F. Cheng, A.-W. Liu, J.-T. Zhang, S.-M. Hu, ``Application of cavity ring-down spectroscopy to the Boltzmann constant determination,'' Opt. Express, \textbf{19}, 19993 (2011) } combined with a temperature-stabilized sample cell. The temperature fluctuation of the gas sample cell is kept below 1 mK for hours. The probing laser is frequency locked at a longitudinal mode of a Fabry-P\'{e}rot interferometer made of ultra-low-expansion glass, and the spectral scan is implemented by scanning the sideband produced by an electro-optic modulator. As a result, a kHz precision has been maintained during the measurement of the spectrum of 10 GHz wide. A ro-vibrational line of C$_2$H$_2$ is measured at sample pressures of a few Pa. Using a pair of mirrors with a reflectivity of 0.99997 at 787 nm, we are able to detect absorption line profiles with a signal-to-noise ratio of $10^5$. Fitting of the recorded spectra allows us to determine the Doppler width with a statistical uncertainty of 10 ppm. Further improvements on the experimental reproducibility and investigations on the collision effects will probably lead to an optical determination of the Boltzmann constant with an uncertainty of a few ppm. %\begin{thebibliography}{2}% %\bibitem {Pan2011RSI_LL_CRDS}% % H. Pan, C.-F. Cheng, Y.~R. Sun, B. Gao, A.-W. Liu, S.-M. Hu, % ``Laser-locked, continuously tunable high resolution cavity ring-down spectrometer,'' % Rev. Sci. Instrum. \textbf{82}, 103110 (2011) % %\bibitem {Sun2011OE}% % Y.~R. Sun, H. Pan, C.-F. Cheng, A.-W. Liu, J.-T. Zhang, S.-M. Hu, % ``Application of cavity ring-down spectroscopy to the Boltzmann constant determination,'' % Opt. Express, \textbf{19}, 19993 (2011) % %\end{thebibliography}%
- Publisher
- International Symposium on Molecular Spectroscopy
- Type of Resource
- text
- Language
- English
- Permalink
- http://hdl.handle.net/2142/51149
- DOI
- https://doi.org/10.15278/isms.2014.TJ12
- Copyright and License Information
- Copyright 2014 by the authors. Licensed under a Creative Commons Attribution 4.0 International License. http://creativecommons.org/licenses/by/4.0/