Withdraw
Loading…
Headspace Analysis Of Volatile Compounds Using Segemented Chirped-pulse Fourier Transform Mm-wave Spectroscopy
Pate, Brooks
Loading…
Permalink
https://hdl.handle.net/2142/51175
Description
- Title
- Headspace Analysis Of Volatile Compounds Using Segemented Chirped-pulse Fourier Transform Mm-wave Spectroscopy
- Author(s)
- Pate, Brooks
- Contributor(s)
- Steber, Amanda
- Harris, Brent
- Issue Date
- 2014-06-16
- Keyword(s)
- Analytical, Combustion, Plasma
- Abstract
- A chirped-pulse Fourier transform mm-wave spectrometer has been tested in analytical chemistry applications of headspace analysis of volatile species. A solid-state mm-wave light source (260-290 GHz) provides 30-50 mW of power. This power is sufficient to achieve optimal excitation of individual transitions of molecules with dipole moments larger than about 0.1 D. The chirped-pulse spectrometer has near 100\% measurement duty cycle using a high-speed digitizer (4 GS/s) with signal accumulation in an FPGA. The combination of the ability to perform optimal pulse excitation and near 100\% measurement duty cycle gives a spectrometer that is fully optimized for trace detection. The performance of the instrument is tested using an EPA sample (EPA VOC Mix 6 – Supelco) that contains a set of molecules that are fast eluting on gas chromatographs and, as a result, present analysis challenges to mass spectrometry. The ability to directly analyze the VOC mixture is tested by acquiring the full bandwidth (260-290 GHz) spectrum in a “high dynamic range” measurement mode that minimizes spurious spectrometer responses. The high-resolution of molecular rotational spectroscopy makes it easy to analyze this mixture without the need for chemical separation. The sensitivity of the instrument for individual molecule detection, where a single transition is polarized by the excitation pulse, is also tested. Detection limits in water will be reported. In the case of chloromethane, the detection limit (0.1 microgram/L), matches the sensitivity reported in the EPA measurement protocol (EPA Method 524) for GC/MS.
- Publisher
- International Symposium on Molecular Spectroscopy
- Type of Resource
- text
- Language
- English
- Permalink
- http://hdl.handle.net/2142/51175
- DOI
- https://doi.org/10.15278/isms.2014.MJ01
- Copyright and License Information
- Copyright 2014 by the authors. Licensed under a Creative Commons Attribution 4.0 International License. http://creativecommons.org/licenses/by/4.0/