Designing, construction and analysis of line-scanning detection instrument for photonic crystal enhanced fluorescence
Zhu, Chenqi
Loading…
Permalink
https://hdl.handle.net/2142/73102
Description
Title
Designing, construction and analysis of line-scanning detection instrument for photonic crystal enhanced fluorescence
Author(s)
Zhu, Chenqi
Issue Date
2015-01-21
Director of Research (if dissertation) or Advisor (if thesis)
Cunningham, Brian T.
Department of Study
Electrical & Computer Eng
Discipline
Electrical & Computer Engr
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
M.S.
Degree Level
Thesis
Keyword(s)
fluorescence detection
photonic crystal enhanced fluorescence
detection instrument
Abstract
The work presented in this thesis is the designing, construction, and analysis of a portable line-scanning detection instrument for photonic crystal enhanced fluorescence. In order to increase the fluorescence signal for low-concentration detection, we introduced the photonic crystal enhanced fluorescence detection modality and demonstrated that it is a very effective approach to improve the fluorescence signal and hence the signal-to-noise ratio. Past work on the enhanced fluorescence detection instruments is examined in this thesis. We also proposed and developed a computational model for designing the portable line-scanning detection instrument for photonic crystal enhanced fluorescence (PCEF) based on the bench-top line-scanning detection instrument. From the computational model, we concluded that of the several parameters in the instrument, the quantum efficiency and dark current of the camera are very critical for the detection sensitivity. The numerical aperture of the objective is also important in terms of signal collection efficiency.
Based on the computational model, we developed an improved configuration of a portable instrument. The new configuration incorporated changes in components and simplification in design, achieved decrease in cost, and maintained competitive detection sensitivity. Experiments have been run on the new instrument to characterize its performance. The signal-to-noise ratio and detection limit of the portable line-scanning PCEF detection instrument are compared with those of the bench-top line-scanning instrument. Results show that the portable version is able to achieve as low a detection limit as the bench-top line-scanning detection instrument without the electron multiplying effect, while achieved at a decrease in cost and physical size.
Use this login method if you
don't
have an
@illinois.edu
email address.
(Oops, I do have one)
IDEALS migrated to a new platform on June 23, 2022. If you created
your account prior to this date, you will have to reset your password
using the forgot-password link below.