Investigations of an Automated System for Profiling of Serum Constituents in Neonatal Blood Samples
Roth, Michael David
This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/70205
Description
Title
Investigations of an Automated System for Profiling of Serum Constituents in Neonatal Blood Samples
Author(s)
Roth, Michael David
Issue Date
1982
Department of Study
Chemistry
Discipline
Chemistry
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
Ph.D.
Degree Level
Dissertation
Keyword(s)
Chemistry, Pharmaceutical
Abstract
In the past few years pediatric clinical chemistry has received an increasing amount of attention. Pediatric patients, especially neonates, are presently treated quite differently from adults with respect to laboratory testing. Although desirable, profiling is not done on neonatal samples because of the very small samples available. It has been the objective of these studies to determine if a multichannel centrifugal analyzer (MCCA), a sample/reagent handling system, and chemical methods can be developed for profiling serum constituents of neonates.
Characteristics of the system reflect the needs of the patients rather than purely analytical considerations. Some of the characteristics required for the analytical system include: about 20 microliters sample volume for the complete profile; flexibility in choosing profile tests; accuracy and precision comparable to that obtained on larger samples; rapid analysis and reporting of results; and sample identification integrity.
Criteria for the sample/reagent handling system included: adaptability to the existing MCCA; acceptance of the sample from a capillary tube; provision for variable sample dilutions; and a minimum of wasted sample. Modifications made to the MCCA previously developed in our research group include: improved automated control of the MCCA; improved rotor control; improved data interface; addition of temperature control; adaptation of the sample/reagent handling system, addition of a fluorescence channel; design of new MCCA discs and disc holders; and changes in the software. Data are presented that characterize the performance of the MCCA and the sample/reagent handling system.
A panel of tests to evaluate renal function was developed that includes tests for total protein, albumin, calcium, phosphorus, urea nitrogen, and creatinine. An enzymatic creatinine test has been developed that uses five microliters of serum rather than the usual 25 microliters. Adaptations of methods for the other analytes all require between one and four microliters of serum. Therefore a profile of at least six constituents can be obtained on the small samples available from neonates. Data are presented which illustrate the ability of the system to produce clinically useful analyses in both single channel and profile modes.