This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/69930
Description
Title
An Experimental/analytical Study of the Dynamic Response of Staggered Structural Wall Systems
Author(s)
Kreger, Michael Eugene
Issue Date
1983
Department of Study
Civil Engineering
Discipline
Civil Engineering
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
Ph.D.
Degree Level
Dissertation
Keyword(s)
Engineering, Civil
Abstract
The Imperial County Services Building of El Centro, California sustained severe damage during the 15 October 1979 Imperial Valley earthquake. Response of the structure during the earthquake was recorded by 13 strong-motion accelerographs. Vertical-load-carrying and lateral-force-resisting systems are described, and corrected acceleration records, calculated base shear and moment waveforms, response spectra, and Fourier amplitude spectra are presented.
A conceptual model of the N-S lateral-force-resisting system at the east end of the structure was formed. A small-scale reinforced-concrete structure was designed to represent the conceptual model. The small-scale structure was constructed then subjected to simulated earthquake motions to investigate the nonlinear dynamic response of such a lateral-force-resisting system.
Response of the small-scale test structure is interpreted through measured acceleration and displacement response, shear and moment response, Fourier amplitude spectra, and response spectra. Response is studied further using a nonlinear two-degree-of-freedom numerical model.
Using information developed from the experimental study, the recorded data from the Imperial County Services Building is evaluated. Failure of east-end first-story columns is investigated (1) by considering forces to act on the structure in only the N-S or E-W direction, and (2) by estimating axial load-moment combinations resulting from N-S and E-W forces acting simultaneously on the structure.