This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/66906
Description
Title
Influence of Chlorination and the Distribution System on Mutagens in a Potable Water Supply
Author(s)
Clark, Robert Raymond
Issue Date
1981
Department of Study
Civil Engineering
Discipline
Environmental Engineering
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
Ph.D.
Degree Level
Dissertation
Keyword(s)
Environmental Sciences
Language
eng
Abstract
Mutagens were recovered from a Central Illinois potable water supply by adsorption on polyurethane foam plugs. Assay of these concentrates with the Ames Salmonella/microsome reversion assay showed both promutagenic and direct-acting responses in TA98. Examination of the water at the groundwater source, following treatment and after passage through the distribution system, revealed that the level of both direct and activatable mutagenicity increased within the distribution system. The utility studied uses a groundwater source that contains ammonia and methane. To control taste and odor problems the utility alternates disinfection practice from chloramine to chlorination beyond breakpoint at monthly intervals in the summer. We assayed the mutagenicity of the water at weekly intervals and continually through transitions from chloramine to breakpoint and reverse for a period of a year. In general chloramine disinfection produced water with more S-9-dependent than direct-acting mutagenicity. Chlorination beyond breakpoint reversed this order. Detailed examination of the appearance of mutagen and chlorine at the tap showed patterns consistent with the formation of mutagen by reaction of disinfectant with substances in the water, possibly contributed by the distribution system.
Several fire hydrants located on dead ends in the distribution system were flushed and the water collected and extracted. These samples had high amounts of promutagenic activity which was filterable and hence associated with the particulate matter in the water. One of the most potent of these extracts was fractionated by high pressure liquid chromatography. Two known mutagens, benzo(a)pyrene and benz(a)anthracene, were identified in the extract.