Withdraw
Loading…
Elastic-anisotropic properties of the porcine superflexor tendon measured by instrumented indentation
Sangha, Harpreet
Loading…
Permalink
https://hdl.handle.net/2142/49786
Description
- Title
- Elastic-anisotropic properties of the porcine superflexor tendon measured by instrumented indentation
- Author(s)
- Sangha, Harpreet
- Issue Date
- 2014-05-30T17:17:37Z
- Director of Research (if dissertation) or Advisor (if thesis)
- Wagoner Johnson, Amy J.
- Department of Study
- Mechanical Science and Engineering
- Discipline
- Mechanical Engineering
- Degree Granting Institution
- University of Illinois at Urbana-Champaign
- Degree Name
- M.S.
- Degree Level
- Thesis
- Keyword(s)
- nanoindentation
- depth-sensing indentation
- soft tissue
- biomechanics
- tendon anisotropy
- Abstract
- Measurements of soft tissue anisotropy using instrumented indentation are of interest because of the potential for indentation-based clinical diagnostics. Shortage of previous research relating to instrumented indentation of soft tissue in the kPa range, such as tendon, motivated a protocol development phase in our study. Once indents in tendon were repeatedly successful and the protocol validated, elastic-anisotropy in tendon was studied on the premise that collagen fibers in tendon are highly-ordered and unidirectional. Samples of porcine superflexor tendon were mounted for indentation such that the collagen fibers were oriented one of three possible ways relative to the indentation probe: parallel to the probe (longitudinal indentation), perpendicular to the probe (lateral indentation), or 45° to the probe (intermediate indentation). Non-significant differences in the reduced elastic modulus of the three experimental groups suggest that porcine superflexor tendon anisotropy is not detected by instrumented indentation. Contextualizing these results within the concept of indentation strain provides support for the possibility that the critical strain required for the onset of anisotropy in tendon is perhaps beyond the deformation range on the instrumented indentation system. With respect to protocol development for instrumented indentation of soft tissues, new insight is provided into the importance of clearing the indentation probe between successive indents of biological debris to ensure data integrity.
- Graduation Semester
- 2014-05
- Permalink
- http://hdl.handle.net/2142/49786
- Copyright and License Information
- Copyright 2014 Harpreet Sangha
Owning Collections
Graduate Dissertations and Theses at Illinois PRIMARY
Graduate Theses and Dissertations at IllinoisManage Files
Loading…
Edit Collection Membership
Loading…
Edit Metadata
Loading…
Edit Properties
Loading…
Embargoes
Loading…