Detection of hydrogen peroxide and ethanol in exhaled breath using biosensors: Considerations in standardizing breath collection
Chen, Shih-Fang
Loading…
Permalink
https://hdl.handle.net/2142/31994
Description
- Title
- Detection of hydrogen peroxide and ethanol in exhaled breath using biosensors: Considerations in standardizing breath collection
- Author(s)
- Chen, Shih-Fang
- Issue Date
- 2012-06-27T21:23:34Z
- Director of Research (if dissertation) or Advisor (if thesis)
- Danao, Mary-Grace C.
- Doctoral Committee Chair(s)
- Danao, Mary-Grace C.
- Committee Member(s)
- Cadwallader, Keith R.
- Gates, Richard S.
- Zhang, Yuanhui
- Department of Study
- Engineering Administration
- Discipline
- Agricultural & Biological Engr
- Degree Granting Institution
- University of Illinois at Urbana-Champaign
- Degree Name
- Ph.D.
- Degree Level
- Dissertation
- Keyword(s)
- Breath analysis
- exhaled breath
- sampling conditions
- breath collection standardization
- biosensor
- uncertainty analysis
- Abstract
- Breath monitoring is a non-invasive, safe, and repeatable approach to determining the health status of humans and other mammals. Breath samples could be detected in two ways directly sensing exhaled breath (EB) or chilling the EB to obtaining the exhaled breath condensate (EBC). Each has its advantages and disadvantages but they are both affected by different sampling conditions. Additionally, volatile organic compounds (VOCs) and nonvolatile organic compounds (non-VOCs) in the breath matrix are retained differently under varied sampling conditions. The dearth of information on how sampling conditions affect the intrinsic properties of biomarkers in breath and the lack of standardization information hinder the use of breath monitoring in clinical use. The study aims to develop predictive models to standardize the varied sampling conditions of breath temperatures, flow rates, condensing temperatures, and sensing durations in EB and EBC sensing. Ethanol (VOC) and H2O2 (non-VOC) were chosen as model biomarkers, which were potential biomarkers of liver function and respiratory diseases, respectively. A breath output simulator was developed to simulate the conditions of exhaled breath. Screen printed carbon electrodes (SPCEs) were used solely or immobilized with alcohol oxidase as biosensors for detecting the chosen biomarkers amperometrically. Akaike's information criterion, Bayesian information criterion, and cross validation were adopted in predictive model selections, and uncertainty analyses were surveyed to further clarify the margin of doubt for the measurement of each sampling factors. Final predictive models were developed for ethanol in EB and EBC, and H2O2 in EBC for specific sensing time (5 min) and full sensing duration (3-10 min). Results showed that the EBC model for ethanol in 5 min measurement performed a better regression result (R2 = 0.9471) than the EB model for ethanol (R2 = 0.8261) and the EBC model for H2O2 (R2 = 0.8261). Furthermore, in 5 min predictive models, both ethanol and H2O2 concentrations in EBC samples were affected by condensing temperature, but only H2O2 detection was affected by breath temperature and breath rate. The results indicated that sampling conditions were more critical and were more constrained for non-VOC sensing than VOC sensing. Uncertainty analyses showed that the 5 min EBC predictive models had 18.53 – 26.55% percentage uncertainty and the 5 min EB predictive model had up to 44.21% percentage uncertainty. The major source of the uncertainties was due to the sensing system which included the SPCEs and used enzyme.
- Graduation Semester
- 2012-05
- Permalink
- http://hdl.handle.net/2142/31994
- Copyright and License Information
- Copyright 2012 Shih-Fang Chen
Owning Collections
Graduate Dissertations and Theses at Illinois PRIMARY
Graduate Theses and Dissertations at IllinoisManage Files
Loading…
Edit Collection Membership
Loading…
Edit Metadata
Loading…
Edit Properties
Loading…
Embargoes
Loading…