This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/22582
Description
Title
Mass transfer in turbulent pulsating flows
Author(s)
Poirier, Michael Robert
Issue Date
1989
Doctoral Committee Chair(s)
Hanratty, Thomas J.
Department of Study
Chemical and Biomolecular Engineering
Discipline
Chemical and Biomolecular Engineering
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
Ph.D.
Degree Level
Dissertation
Keyword(s)
Engineering, Chemical
Language
eng
Abstract
This thesis reports on the effects of imposed flow oscillations on the mass transfer coefficient and the mass transfer intensity in a turbulent flow.
The equations for the turbulent fluctuations in the velocity and concentration fields and the equations for the mean and oscillating components of the phase averaged concentration field are derived and presented. From examining these equations, one can determine which terms would cause changes in the time averaged velocity and concentration fields and which terms would cause oscillations in the phase averaged velocity and concentration fields.
Experiments were performed in a two inch diameter horizontal pipe. A reciprocating piston pump imposed the pulsations in the mean flow rate. Mass transfer coefficients were measured electrochemically. A platinum plated brass section served as a cathode to measure the average mass transfer coefficient and to insure a fully developed concentration boundary layer. Platinum electrodes, insulated from the cathode, were embedded in the cathode to measure the phase averaged mass transfer coefficient and the fluctuations in the phase averaged mass transfer coefficient. Numerical methods were developed to solve the phase averaged mass balance equation by modeling the phase averaged Reynolds transport with an eddy diffusivity model.
The following results were obtained in this study: The imposed flow oscillations have no effect upon the time averaged mass transfer coefficient or the time averaged mass transfer intensity. The imposed oscillations in the velocity field cause oscillations in the phase averaged mass transfer coefficient and the phase averaged mass transfer intensity. The oscillations in the streamwise velocity fluctuations cause oscillations in the normal velocity fluctuations which cause oscillations in the phase averaged mass transfer coefficient and the phase averaged mass transfer intensity. The pseudo steady state and relaxation eddy diffusivity models provide good agreement with the experimental data at low frequencies of pulsation. However, at high frequencies of pulsation, there is an interaction between the imposed pulsations and the turbulence that is not included in these models. A modified eddy diffusivity model in which the eddy diffusivity is a function of $\omega\sp{+2}$ provided good agreement with the experimental results at all frequencies that were studied.
Use this login method if you
don't
have an
@illinois.edu
email address.
(Oops, I do have one)
IDEALS migrated to a new platform on June 23, 2022. If you created
your account prior to this date, you will have to reset your password
using the forgot-password link below.