The optimal design of groundwater quality monitoring networks under conditions of uncertainty
Meyer, Philip Daniel
This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/22559
Description
Title
The optimal design of groundwater quality monitoring networks under conditions of uncertainty
Author(s)
Meyer, Philip Daniel
Issue Date
1992
Doctoral Committee Chair(s)
Valocchi, Albert J.
Department of Study
Civil and Environmental Engineering
Discipline
Civil and Environmental Engineering
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
Ph.D.
Degree Level
Dissertation
Keyword(s)
Hydrology
Engineering, Civil
Engineering, Sanitary and Municipal
Language
eng
Abstract
The design of a monitoring network to provide initial detection of groundwater contamination at a waste disposal facility is complicated by uncertainty in both the characterization of the subsurface and the nature of the contaminant source. In addition, monitoring network design requires the resolution of multiple conflicting objectives. A method is presented that both incorporates system uncertainty in monitoring network design and provides network alternatives that are noninferior with respect to several objectives. Monte Carlo simulation is the method of uncertainty analysis. The random inputs to the simulation are the hydraulic conductivity field and the contaminant source location. A transport model is used to generate a series of random plumes representing equally likely contamination scenarios. For each plume, the method finds the set of potential monitoring locations at which the plume is detectable. In addition, the area of each plume is recorded at the time when it reaches each potential monitoring location. This information is used to formulate one of two optimization models. The design objectives considered are (1) minimize the number of monitoring wells, (2) maximize the probability of detecting a contaminant leak, and (3) minimize the expected area of contamination at the time of detection. The network design method is applied to a generic problem. Results illustrate the tradeoffs between objectives and the configurations of noninferior network solutions. The probability of detection is increased by using more monitoring wells or by locating the wells farther from the source. The latter case results in an increase in the average area of the detected plumes. If monitoring is carried out very close to the contaminant source to reduce the expected area of a detected plume, a large number of wells is required to provide a high probability of detection. These tradeoffs are an important factor in network design unless the cost (as expressed by the number of monitoring wells) is of limited concern. The importance of using a sufficiently large number of plume realizations in the Monte Carlo simulation is demonstrated. Finally, a sensitivity analysis illustrates the importance of several model parameters, including the hydraulic conductivity field variance and correlation scale, the transverse dispersivity, and the size of the contaminant source.
Use this login method if you
don't
have an
@illinois.edu
email address.
(Oops, I do have one)
IDEALS migrated to a new platform on June 23, 2022. If you created
your account prior to this date, you will have to reset your password
using the forgot-password link below.