Evaluation of two RC buildings retrofit with steel bracing
Downs, Ruth E.
This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/21095
Description
Title
Evaluation of two RC buildings retrofit with steel bracing
Author(s)
Downs, Ruth E.
Issue Date
1992
Doctoral Committee Chair(s)
Hjelmstad, Keith D.
Department of Study
Civil and Environmental Engineering
Discipline
Civil Engineering
Degree Granting Institution
University of Illinois at Urbana-Champaign
Degree Name
Ph.D.
Degree Level
Dissertation
Keyword(s)
Engineering, Civil
Language
eng
Abstract
Experimental and analytical studies were conducted to assess the contributions of two retrofit schemes to the performances of two RC buildings during the 1985 Mexico earthquake. The schemes used to strengthen the two buildings were similar in that diagonal steel braces and RC infill walls were used to stiffen and strengthen the existing frames. The schemes were different in that one had steel bracing in the interior of the building while the other had steel bracing on the exterior of the building.
The evaluations of the retrofit schemes considered a variety of data including: (1) observations on earthquake damage from the 1979 Mexico earthquake, which occurred before the retrofit schemes were implemented; (2) ambient vibration measurements before and after retrofit; (3) observations on earthquake damage from the 1985 Mexico earthquake; (4) forced vibration tests after the 1985 earthquake; and (5) analytical studies using various models of the buildings based upon the building plans and other observations.
The results of the studies indicate that the additional stiffness and strength provided by the retrofit elements were essential to the survival of the two buildings during the 1985 earthquake, that the effects of soil-structure interaction must be considered when designing retrofit systems for soft soil sites, and that connections play an important role in determining the effectiveness of the retrofit elements.
Use this login method if you
don't
have an
@illinois.edu
email address.
(Oops, I do have one)
IDEALS migrated to a new platform on June 23, 2022. If you created
your account prior to this date, you will have to reset your password
using the forgot-password link below.