Withdraw
Loading…
Domestic graywater heat recovery from the UIUC 2009 solar decathlon house
Cirone, Christopher T.
Loading…
Permalink
https://hdl.handle.net/2142/18575
Description
- Title
- Domestic graywater heat recovery from the UIUC 2009 solar decathlon house
- Author(s)
- Cirone, Christopher T.
- Issue Date
- 2011-01-21T22:47:05Z
- Director of Research (if dissertation) or Advisor (if thesis)
- Wang, Xinlei
- Department of Study
- Engineering Administration
- Discipline
- Agricultural & Biological Engr
- Degree Granting Institution
- University of Illinois at Urbana-Champaign
- Degree Name
- M.S.
- Degree Level
- Thesis
- Keyword(s)
- graywater
- greywater
- gray water
- grey water
- drain water
- heat recovery
- domestic
- residential
- energy recovery
- domestic hot water
- shower water
- Abstract
- This study investigates the potential for waste water heat recovery in a residential application. A heat exchanger is utilized to transfer heat from the waste water drain line of a residence to the incoming water supply line. An experiment is conducted on the University of Illinois 2009 Solar Decathlon competition home to quantify the benefit of a heat recovery system that utilizes a counter flow flat plate heat exchanger in a balanced flow configuration. This system recovers heat in a non-regenerative scheme (meaning that it does not retain the discharge water for batch heat recovery) and is capable of reducing the hot water energy demand the home. This system is designed to benefit appliances like showers and sinks that drain simultaneous to the make-up water demand. The results of the experiment indicate that up to 37% of the thermal energy used by a shower can be recovered with the system developed in this study. These results are based on a drainage water temperature of 101 °F (38 °C) and a supply water temperature of 76 °F (24 °C) at an average effluent mass flow rate of 6.74 kg/s. Flow rate is determined to have a positive correlation to the magnitude of recoverable heat, although the heat recovery percentage has marginal difference for the low, medium, and high flow rates tested. The heat recovery percentage was 34%, 37%, and 33% for the low, medium, and high flow rates tested. It is further estimated that the heat recovery percentage would increase as the supply water temperature decreases. An estimate is conducted that shows the heat recovery percentage for each flow case would increase to 41%, 44%, and 38% respectively if the supply water temperature was reduced to 55 °F (12.8 °C).
- Graduation Semester
- 2010-12
- Permalink
- http://hdl.handle.net/2142/18575
- Copyright and License Information
- Copyright 2010 Christopher T. Cirone
Owning Collections
Graduate Dissertations and Theses at Illinois PRIMARY
Graduate Theses and Dissertations at IllinoisManage Files
Loading…
Edit Collection Membership
Loading…
Edit Metadata
Loading…
Edit Properties
Loading…
Embargoes
Loading…