Withdraw
Loading…
Destructive Testing of IDOT Bridge Structure Number 020-3087
Golecki, Thomas F.; Spencer, B.F.
Loading…
Permalink
https://hdl.handle.net/2142/107800
Description
- Title
- Destructive Testing of IDOT Bridge Structure Number 020-3087
- Author(s)
- Golecki, Thomas F.
- Spencer, B.F.
- Issue Date
- 2020-08
- Keyword(s)
- Load Tests
- Prestressed Concrete Bridges
- Structural Deterioration and Defects
- Laboratory Tests
- Abstract
- The partial collapse of Illinois Department of Transportation structure 020-3087 on October 1, 2019, provided IDOT with the opportunity to evaluate the in situ strength of a precast, prestressed concrete deck beam bridge after 50 years in service. An undamaged beam was transported to the Newmark Structural Engineering Laboratory and tested in three-point bending to failure on February 25, 2020. The beam supported a peak load of 33.14 kips before failure, an ultimate moment of 227.5 kip-ft. Upon failure, the concrete around the prestressing strands was removed to expose the strands. All strands were present; however, the strands were in a different configuration than shown on design drawings. None of the strands showed visible corrosion.
- Publisher
- Illinois Center for Transportation/Illinois Department of Transportation
- Series/Report Name or Number
- FHWA-ICT-20-008
- ISSN
- 0197-9191
- Type of Resource
- text
- Language
- en
- Permalink
- http://hdl.handle.net/2142/107800
- DOI
- https://doi.org/10.36501/0197-9191/20-014
- Sponsor(s)/Grant Number(s)
- IDOT-R27-SP42
- Copyright and License Information
- No restrictions. This document is available through the National Technical Information Service, Springfield, VA 22161.