Withdraw
Loading…
Dual-comb up-conversion detection of fundamental molecular transitions
Chen, Zaijun
Loading…
Permalink
https://hdl.handle.net/2142/104552
Description
- Title
- Dual-comb up-conversion detection of fundamental molecular transitions
- Author(s)
- Chen, Zaijun
- Contributor(s)
- Picqué, Nathalie
- Hänsch, Theodor W.
- Issue Date
- 2019-06-17
- Keyword(s)
- Instrument/technique demonstration
- Abstract
- "\begin{wrapfigure}{r}{0pt} \includegraphics[scale=0.6]{spec6.eps} \end{wrapfigure} We present a new approach to mid-infrared dual-comb spectroscopy. Strong fundamental ro-vibrational transitions are interrogated in the mid-infrared 3-$\mu$m region, while the detection is performed in the near-infrared telecommunication region where sensitive opto-electronic tools are available. Using difference-frequency generation, a near-infrared comb is converted to the range of 2700-3400 \wn, where it interacts with the sample before being converted back to the telecommunication region. There, it beats with a second comb of slightly different line spacing for multiheterodyne detection. The broadband spectra obtained within arbitrarily long averaging time show resolved comb lines, a frequency scale calibrated within the accuracy of an atomic clock and a negligible contribution of the instrument line shape, as in previous reports using our recent scheme of feed-forward stabilization\footnote{Z. Chen, M. Yan, T. W. H\""{a}nsch, and N. Picqu\'{e}, A phase-stable dual-comb interferometer, Nat Commun 9, 3035 (2018).}$^{,}$\footnote{Z. Chen, T. W. H\""{a}nsch, and N. Picqu\'{e}, Mid-infrared feed-forward dual-comb spectroscopy, Proc Natl Acad Sci USA 116, 3454-3459 (2019).}. A spectrum (Fig. a, expanded view on a single comb line on the radio-frequency scale in Fig.b) in the region of the {\it Q }-branch of the \nub{3} band of $^{12}$CH$_{4}$, is measured within 1000 s. The molecular profiles are sampled by the comb at a resolution of 3.3 10$^{-3}$ \wn (Fig.c) across a total span of 50 \wn, with an average signal-to-noise ratio of 2540. Comparisons with direct mid-infrared detection will be discussed."
- Publisher
- International Symposium on Molecular Spectroscopy
- Type of Resource
- text
- Language
- eng
- Permalink
- http://hdl.handle.net/2142/104552
- DOI
- https://doi.org/10.15278/isms.2019.MJ02
- Copyright and License Information
- Copyright 2019 Zaijun Chen