Withdraw
Loading…
Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures
Fent, Kenneth W.; Alexander, Barbara; Roberts, Jennifer; Robertson, Shirley; Toennis, Christine; Sammons, Deborah; Bertke, Stephen; Kerber, Stephen; Smith, Denise L.; Horn, Gavin P.
Loading…
Permalink
https://hdl.handle.net/2142/101922
Description
- Title
- Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures
- Author(s)
- Fent, Kenneth W.
- Alexander, Barbara
- Roberts, Jennifer
- Robertson, Shirley
- Toennis, Christine
- Sammons, Deborah
- Bertke, Stephen
- Kerber, Stephen
- Smith, Denise L.
- Horn, Gavin P.
- Issue Date
- 2017-06-21
- Keyword(s)
- Firefighters
- Life safety
- Firefighting research
- Personal protective equipment
- Hydrocarbons
- Decontamination
- Abstract
- Firefighters’ skin may be exposed to chemicals via permeation/penetration of combustion byproducts through or around personal protective equipment (PPE) or from the cross-transfer of contaminants on PPE to the skin. Additionally, volatile contaminants can evaporate from PPE following a response and be inhaled by firefighters. Using polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) as respective markers for non-volatile and volatile substances, we investigated the contamination of firefighters’ turnout gear and skin following controlled residential fire responses. Participants were grouped into three crews of twelve firefighters. Each crew was deployed to a fire scenario (one per day, four total) and then paired up to complete six fireground job assignments.Wipe sampling of the exterior of the turnout gear was conducted pre- and post-fire.Wipe samples were also collected from a subset of the gear after field decontamination. VOCs off-gassing from gear were also measured pre-fire, post-fire, and post-decon. Wipe sampling of the firefighters’ hands and neck was conducted pre- and post-fire. Additional wipes were collected after cleaning neck skin. PAH levels on turnout gear increased after each response and were greatest for gear worn by firefighters assigned to fire attack and to search and rescue activities. Field decontamination using dish soap, water, and scrubbing was able to reduce PAH contamination on turnout jackets by a median of 85%. Off-gassing VOC levels increased post-fire and then decreased 17–36 min later regardless of whether field decontamination was performed. Median post-fire PAH levels on the neck were near or below the limit of detection (<24 micrograms per square meter [μg/m2]) for all positions. For firefighters assigned to attack, search, and outside ventilation, the 75th percentile values on the neck were 152, 71.7, and 39.3 μg/m2, respectively. Firefighters assigned to attack and search had higher post-fire median hand contamination (135 and 226 μg/m2, respectively) than other positions (<10.5 μg/m2). Cleansing wipes were able to reduce PAH contamination on neck skin by a median of 54%.
- Publisher
- Journal of Occupational and Environmental Hygiene
- Type of Resource
- text
- Language
- en
- Permalink
- http://hdl.handle.net/2142/101922
- DOI
- 10.1080/15459624.2017.1334904
- Sponsor(s)/Grant Number(s)
- This study was funded through a U.S. Department of Homeland Security, Assistance to Firefighters Grant (EMW-2013- FP-00766). This project was also made possible through a partnership with the CDC Foundation.
- Copyright and License Information
- This article not subject to U.S. copyright law.
Owning Collections
IFSI Research PRIMARY
This collection contains research publications from IFSI Research at the Illinois Fire Service Institute.Manage Files
Loading…
Edit Collection Membership
Loading…
Edit Metadata
Loading…
Edit Properties
Loading…
Embargoes