Measuring conformational energy differences using pulsed-jet microwave spectroscopy
Funderburk, Cameron M.
Loading…
Permalink
https://hdl.handle.net/2142/96980
Description
Title
Measuring conformational energy differences using pulsed-jet microwave spectroscopy
Author(s)
Funderburk, Cameron M.
Contributor(s)
Brown, Gordon G.
Taylor, Tiffany R.
Gaster, Sydney A.
Issue Date
2017-06-20
Keyword(s)
Instrument/technique demonstration
Abstract
The conformational energy differences of various chemicals have been measured using chirped-pulse Fourier transform microwave (CP-FTMW) spectroscopy. The hypothesis is that the relative intensities measured in a pulsed-jet instrument are proportional to the conformer populations present before the expansion occurs. Therefore, by measuring the relative intensities in a CP-FTMW spectrum, we aim to determine the relative energy difference between conformers. Experimentally, pulsed-jet CP-FTMW data will be compared to energy differences reported in the literature and to room-temperature CP-FTMW data acquired at Coker College. Results from emph{ab initio} calculations will also be used for comparison.