Effect of null subtraction imaging technique on grating lobes
Min, Byung Hoon
This item is only available for download by members of the University of Illinois community. Students, faculty, and staff at the U of I may log in with your NetID and password to view the item. If you are trying to access an Illinois-restricted dissertation or thesis, you can request a copy through your library's Inter-Library Loan office or purchase a copy directly from ProQuest.
Permalink
https://hdl.handle.net/2142/97872
Description
Title
Effect of null subtraction imaging technique on grating lobes
Author(s)
Min, Byung Hoon
Contributor(s)
Oelze, Michael L.
Issue Date
2017-05
Keyword(s)
null subtraction imaging
apodization
ultrasound
Abstract
In ultrasonic imaging, the presence of grating lobes results in imaging artifacts, causing image degradation and distortion. The grating lobes occur when the center-to-center spacing between elements of the arrays, i.e., the pitch, of the transducer is greater than or equal to the wavelength. When the pitch size of the array is smaller, the presence of grating lobes is determined by the steering angle. Generally, apodization is used to reduce the amplitude of the side lobes at the expense of widening the main lobe, which decreases the lateral resolution. Null subtraction imaging (NSI) is a non-linear imaging processing technique that uses three different apodization functions to decrease the amplitude of the side lobes while dramatically improving the lateral resolution. Due to the subtraction involved in the nonlinear processing scheme, we hypothesized that the NSI would also reduce the grating lobe levels. To appraise the performance of the NSI technique on grating lobes, theoretical simulations were performed using Field-II and experimental measurements were performed using an L9-4/38 array connected to an Ultrasonix Tablet system with a SonixDAQ to scan a single wire target. The image was reconstructed using delays to acquire grating lobes when steered, and then beamformed with NSI and rectangular apodization to compare the amplitudes and spot sizes of grating lobe levels. The simulation results revealed up to six times decrease in the grating lobe to main lobe ratio for NSI compared to rectangular apodization, while experimentally the grating lobe to main lobe ratio hardly showed changes. The experimental results showed that the grating lobe appeared very thin and confined with the spot size of 0.09 mm^2 for the NSI compared to 2.03 mm^2 for the rectangular apodization.
Use this login method if you
don't
have an
@illinois.edu
email address.
(Oops, I do have one)
IDEALS migrated to a new platform on June 23, 2022. If you created
your account prior to this date, you will have to reset your password
using the forgot-password link below.