IDEALS Home University of Illinois at Urbana-Champaign logo The Alma Mater The Main Quad

The Effect of Frosting on the Performance of Domestic Refrigerator-Freezer Finned Tube Evaporator Coils

Show full item record

Bookmark or cite this item: http://hdl.handle.net/2142/9688

Files in this item

File Description Format
PDF TR001.pdf (11MB) ACRC Technical Report 01 PDF
Title: The Effect of Frosting on the Performance of Domestic Refrigerator-Freezer Finned Tube Evaporator Coils
Author(s): Rite, R.W.
Contributor(s): Crawford, R.R.
Subject(s): domestic refrigerator freezers evaporator performance
Abstract: The effect of frost formation on the performance of a domestic refrigerator-freezer evaporator coil was investigated. A low temperature evaporator test facility was developed to closely simulate refrigerator-freezer conditions. The rate of frost deposition on the evaporator was determined to be constant with respect to time for a ten-hour testing period over a range of air inlet temperatures and relative humidities, refrigerant temperatures, and airflow rates. Higher humidities and air inlet temperatures and lower refrigerant temperatures were found to increase the frosting rate significantly. Varying the airflow rate was found to slightly affect the frosting rate. Increasing the airflow rate increased the frosting rate a small amount, while, decreasing the airflow rate decreased the frosting rate an equally small amount. However, it appears that the actual correlation between airflow rate and frosting rate is not this straight-forward, but is, instead, the result of the influences of the mass transfer coefficient, the evaporator surface temperature, and the air moisture capacity. How these factors balance one another determines the actual relationship between frost rate and airflow. rate. In addition to these findings, it was found that the UA-value of the evaporator increased as frost was-deposited on the coil while a constant airflow rate was maintained through the coil. The increase at the highest frosting rates was on the order of 40% but was accompanied by an exponentially increasing air side pressure drop.
Issue Date: 1990-08
Publisher: Air Conditioning and Refrigeration Center. College of Engineering. University of Illinois at Urbana-Champaign.
Series/Report: Air Conditioning and Refrigeration Center TR-01
Genre: Technical Report
Type: Text
Language: English
URI: http://hdl.handle.net/2142/9688
Sponsor: Air Conditioning and Refrigeration Center Project 02
Date Available in IDEALS: 2009-03-04
Identifier in Online Catalog: 3366225
 